Telex MCE325 User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
1-6 MCE325 User Instructions
Connectors
Intercom Line Connector XLR type, 3-pin (male-female loop through on two-wire
channel 1 and 2, or four-wire channel A; Female only on
two-wire channel 3 and 4, or four-wire channel B
Dynamic Mic XLR type, 6-pin female
Carbon Mic ¼-inch phone jack, 3-circuit
Auxiliary Connector 25-pin, female, D-Sub
Program Inputs ¼-inch phone jack, 3-circuit
Speaker Output ¼-inch phone jack, 3-circuit
Panel Mic ¼-inch phone jack, metal busing, 3-circuit
MCS325 Specifications
The MCS325 is designed for use with MCE325, but may also be used as a general-purpose
monitor for program material.
Impedance 8 ohms (DCR5.5 to 7 ohms)
Power Rating 5W RMS continuous
Sensitivity 90 dB ±2 dB/2.83 volts/one meter on axis averaged over
one octave bands centered at 250 Hz, 500 Hz, 1 kHz,
2 kHz, 4 kHz, and 8 kHz when enclosed in a sealed box
of 1.3 liters volume.
Frequency Response 200 Hz to 10 kHz ±4 dB on 1/10 octave measurement in
1.3 liter sealed box.
Free Air Resonance 200 Hz to 250 Hz
Distortion Less than 10% @ 5W at resonance.
Stray Magnetic Field Less than 1 gauss at 1 cm from chassis.
Mechanical Noise Unit to be free of buzzes and rattles at 5 W sine wave
input from 100 Hz to 10 kHz.
Figure 1.2
Standard two-channel, two-wire configuration.